-40%

Internet/Ethernet Eight Channel Relay Board: Web TCP/IP Telnet E-mails HTTP API

$ 84.87

Availability: 202 in stock
  • All returns accepted: Returns Accepted
  • Country of Manufacture: Bulgaria
  • Model: Relays
  • Restocking Fee: No
  • Condition: New
  • MPN: DAE-RB/Ro8-12V + DAEnetIP3-ET
  • Item must be returned within: 30 Days
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Brand: Denkovi
  • Return shipping will be paid by: Buyer

    Description

    Internet/Ethernet Eight Channel Relay Board: Web TCP/IP Telnet E-mails HTTP API
    This is Internet/Ethernet 8 channel SPDT relay kit (board) for remote management and control with Virtual Serial Port, TCP/IP, Web, HTTP API, Telnet and serial commands access. It has 8 SPDT Relays, 8 digital inputs (0-3.3V), 8 analog inputs (0-2.048V) and one UART port. Inputs can be adjusted to control relays (standalone work). Also inputs of one controller can control outputs of another over the LAN/WAN (box-to-box mode). It can send E-mails on inputs change as well. Suitable for remote control, home automation, data acquisition, sensor processing, alarm systems, PLC applications.
    Now with free Android and iOS mobile App!
    Features
    10/100 Mbit Ethernet interface with Link Led. Auto MDIX
    UART interface for RS232/RS485 serial connection with other such controllers. UART can be used also for configuration of the parameters
    Power supply voltage: 12VDC;
    Power supply consumption (max): 400mA / 12VDC;
    8
    SPDT relay
    channels (the type depends on the stocks quantity in our store):
    TONGLING -
    JQC-3FF-S-Z
    (10A / 250VAC, 15A / 120VAC, 10A / 28VDC)
    SUNHOLD -
    RAS xx15
    (10A / 250VAC, 15A / 120VAC, 15A / 24VDC)
    1 x 8 digital inputs. Levels: 0 - 3.3VDC
    1 x 8 analog inputs (0 - 2.048VDC input range). Referent voltage: 2.048 V, resolution: 10 bits
    (for series after 06 Nov 2017)
    On boot the outputs are set with states before reset
    Built in RTC (Real Time Clock). It can be synchronized via NTP manually or automatically each 6 hours
    Capacitor power backup keeps time for days during power failure
    Virtual Serial Port - it may be accessed with Serial RS232 commands over TCP/IP network
    Integrated WEB server with password and features like Ajax parameters reading
    Telnet commands
    HTTP API commands
    TCP/IP ASCII protocol with optional RC4 encryption
    All the network ports can be defined by the user
    Supports ICMP (ping)
    19 modes for I/O lines such as inverting, timer, pulses, setting output via input and switch ON/OFF according particular time (scheduling)
    Any input may be referred to control any output of this or another controller in the TCP/IP network
    Linearization for the analog inputs
    Box-to-Box (distributed) mode
    SMTP with authentication (SSL is not supported)
    E-mail notifications for various events
    IP address protection
    Power and status led
    DAEnetIP3 documentation:
    DAEnetIP3 user's manual
    The auction includes
    1 x
    DAEnetIP3 - ET Ethernet controller
    - user manual
    DAEnetIP3_UM.pdf
    1 x 8 Output Channel Relay Board
    1 x Flat ribbon labeled cabel
    3 x plastic spacers
    DRM Software
    - Denkovi Relay Manager Software. The software is available for download from this link -
    setup.exe
    Application Examples
    Remote electrical devices control
    Sensor information processing (temperature, humidity, distance...)
    Management/monitoring for industrial
    It may be used for simple standalone web based thermostat
    Remote Lock/unlock doors
    Home automation
    Alram applications
    Standalone PLC applications
    Controlling another such device over the LAN/WAN without PC (Box-To-Box)
    Instructions
    Bellow is given shortcut for instructions how to connect the KIT or only
    DAEnetIP3-EX
    for first time to router with UTP cable. In the
    user's manual
    are shown the rest connection types.
    Connect DAEnetIP3 RJ45 port with UTP (doesn’t matter crossover or straight) cable.
    Connect PC with the other side of the UTP cable.
    Change the IP of the PC. It may be for example 192.168.0.1. (DAEnetIP3 is with 192.168.0.100).
    Supply DAEnetIP3 with power supply 12VDC (the middle pin of DAEnetIP3 power jack is +12VDC). The power led (with red color) must be on.
    Open your browser (IE, Firefox, Opera) and type 192.168.0.100 in the address bar.
    Use
    admin
    for password.
    Open admin settings.
    Change the Eth IP address of DAEnetIP3. Make it to be in one network with your router and PC. For example if your router is with IP 192.168.0.1 and PC with 192.168.0.101, make DAEnetIP3 with 192.168.0.100. Eth mask must be 255.255.255.0 and Eth gateway 192.168.0.1 (router IP)
    Click “Save” button.
    Unplug the power supply.
    Disconnect the UTP cable from PC and connect it to the router.
    Supply again the DAEnetIP3
    Open browser and type 192.168.0.100.
    Now you may access the DAEnetIP3 controller with router via router from PC
    Please pay attention that:
    the middle pin of the power jack is +12VDC
    There is not protection against reverse voltage.
    Inproper power supply voltage will damage the device !
    We recommend to use this 12VDC Power Supply Adaptor (
    SYS1357-2412
    ) that may be found also in our store. Please contact with us if you have questions. We sell the adaptor with one of the AC plugs for: USA, UK, EU, AUS.
    Note the Power adapter is not included in the auction, we just recommend to use it with the dvice!
    It is sold separately. You may find it in our store!
    Schematics
    Single relay channel (for 12VDC version)
    How to connect lamp to relay channel
    I/O Ports
    The I/O controller has many modes for its inputs/outputs and all of them can be configurated by the user. The controller allows for example analog/digital inputs to control digital outputs, digital outputs to be switched based on 2 events per day (using build in Real Time Clock), generating pulses, timers and so on. You can refer to the user manual for more info.
    16 Digital Outputs (Port A)
    DAEnetIP3 has 16 digital outputs working in 19 different modes. However the relay bord has only 8 relay outputs. So to set the relays you need to change PortA.0 - PortA.7. Relay1 is connected to PortA.0, Relay8 to PortA.7. On the PCB this is marked as PortA_1. When the output level is 0, the relay is OFF. When it is 1, the relays is ON.
    8 Digital Inputs (Port B)
    DAEnetIP3 has 8 digital inputs. They work with +3.3V logic (Low level is 0V, high level is 3.3V). They work in 3 different modes. When the controller digital inputs pins are not connected the pins are in high level (there is connected pull up resistor 10K to each digital input). The input may be tracked only, may control some PortA digital output (this means the relay board also) by rising/falling edge or it may control even output from another DAEnetIP3 controller (Box-To-Box).
    8 Analog Inputs (Port C)
    DAEnetIP3 has 8 analog inputs with 2.048 VDC reference voltage source and 10 bit resolution. The inputs can be only monitored, can control some PortA digital output (this means the relay board also) by crossing threshold or it can control even output from another DAEnetIP3 controller (Box-To-Box). The inputs can also be calibrated softwarely according your hardware application so they can be retreived directly in desirable units (C,V,m...).This is so called linearization.
    Mobile Apps
    DAE-iModules iOS mobile App
    - 100% FREE
    DAE-aModules Android mobile App
    - 100% FREE
    Some useful information about
    DAE-iModules/DAE-aModules
    and
    DAEnetIP3
    :
    Select device
    DAEnetIP3
    . Enter the IP, HTTP Port and web password for the device
    Tab "Other" contains the analog input values for the hardware linearization (by DAEnetIP3) while tab "Analog Inputs" shows their original values
    To connect and scale the analog inputs with sensors, please refer to this link:
    https://denkovi.com/connecting-analog-sensors-to-daenetip3
    Control via DRM Software
    Denkovi Relay Manager (DRM) is multiplatform software for easy controlling all kinds of Denkovi relay boards (USB,SNMP,TCP/IP)
    CAUTION! Using of Denkovi Relay Manager (DRM) Software with devices which are not manufactured by Denkovi Assembly Electronics LTD is not allowed!
    The item is supported by DRM Software. DRM Software will hep you to save money for expensive software and time in programming. It allows you to switch ON/OFF your devices at particular date and time, turn ON/OFF the relays with pulses or control them via specific sequence. If you have ordered at least one of our relay boards from this
    list
    you may turn your PC in powerful automation tool.
    Multiplatform software: supported by Windows/Linux (ver. 2.0)
    Control up to 32 relay boards
    User-friendly intuitive interface
    Save/Load file
    Control mode: single and multiple setting of the relays
    Single pulse with adjustable delay from the control mode (ver. 2.0)
    Timer mode: create timer playlist for the relays
    Weekly mode: each relay may be turned ON/OFF on each day of the week
    Calendar mode: each relay may be turned ON/OFF on particular date at particular time
    Pulse mode: each relay may work in pulse mode by setting duration for ON and duration for OFF. Adjustable number of pulses (ver. 2.0)
    Each relay from each relay board can work independently in some of the five modes
    Each relay board and each relay can be named by the user
    Indicator panel
    Auto load function - the last working file is loaded when DRM is started
    Auto connect function - when the relay board is disconnected DRM will keep trying to find and when this is done, the relay board will be connected again
    Auto start function - DRM software starts when the OS starts (currently this is not available for Windows 8 and Linux)
    Auto set function - DRM will set the relays automatically when the relay board is connected
    Possibility of DRM to starts when PC boots and continues to work from the last saved point
    For more information about DRM Software, screen-shots, detailed description and download -
    here
    How to access the ip controller
    DAEnetIP3 Manager
    Virtual Serial Port (Virtual Com Port)
    DAEnetIP3 and all devices that are based on it may be accessed/controlled via Virtual Serial Port. In other words the the device in this auction may be accessed via COM Port RS232 commands from your computer because it will apear as COM Port:
    DAEnetIP3-Ex
    appears as VSP (COM Port) on your PC
    It may be accessed with any Serial Terminal (for exaple HyperTerminal)
    The only thing the user has to do is to send and receive commands via the COM Port. All the TCP/IP commnucation is done by the driver.
    There is not matter if your DAEnetIP3 device is connected to your PC over LAN cable or Wireless Wi-Fi network, it will appear as VSP (COM Port) on your PC. You need to set only the proper IP, Port and COM Port Name.
    Example commands and responses that are sent/received via the DAEnetIP3 VSP (COM Port). The serial address of DAEnetIP3 is 00.
    Get Digital Input 1 level (Din1), counting in the commands is zero based:
    Send
    :
    00BV0=?;
    Receive
    :
    00BV0=0;
    //The level is low
    Get Analog Input 1 level (Ain1), counting in the commands is zero based:
    Send
    :
    00CV0=?;
    Receive
    :
    00CV0=512;
    Set Digital Output 12 (Do12) in High level, counting in the commands is zero based:
    Send
    :
    00ASB=1;
    Receive
    :
    00ASB=1;
    Get the Ethernet IP address of the module.
    Send
    :
    00MIP=?;
    Receive
    :
    00MIP=192.168.0.100;
    All the commands are described in the user manual
    DAEnetIP3_UM.pdf
    Web browser
    DAEnetIP3 has built-in web server for configuration. All the parameters can be accessed via web browsers like Mozilla, IE and Opera. The pages for I/O ports are refreshed automatically. In this way it is possible to track all the I/O states in real time without manually refreshing the page. The web browser must support JavaScript.
    The page below the text shows the page for the analog inputs. Their states are automaticaly refreshed each 2-3 seconds. The user doesn't have to click refresh button each time but just tracks the I/O changing values almost in real time (Ajax).
    TCP/IP commands
    DAEnetIP3 controller has possibility for access via TCP/IP socket. The user may connect with custom software to port (default is 1010) that is defined for socket based TCP/IP communication.
    The protocol is not based on some standart, but it is developed especially for the DAEnetIP3 controller. The full description of the protocol may be found in the user manual. It is fully ASCII (strings).
    The reason for creating such communiation way is that TCP/IP sockets are widely used in all programing languages.In this way you may create software for DAEnetIP3 without learning difficult and heavy protocols.
    The controller supports RC4 encryption/decription for the TCP/IP socket comunication. This is security measure that gives you basic protection.
    Another security option is IP address protection, that allows only one IP to access the DAEnetIP3 via Web, Socket and Telnet.
    Example commands:
    Set Digital Output 1 in Low state
    Send: 00AS0=0;
    Receive: 00AS0=0;
    Get Analog input 1 value
    Send: 00CV0=?;
    Receive: 00CV0=512;
    HTTP API commands
    Bellow are shown example commands. Please note that there is HTTP API password (by default it is admin) to prevent unauthorized access.
    Example commands:
    send: http://your.ip.address/command.html?
    P=admin&ASG=?&
    (get the whole PortA status of DAEnetIP3)
    receive:

    ASG=0F0F;

    send:http://your.ip.address/command.html?
    P=admin&ASG=?&BVG=?&CV0=?&
    (send several commands at a time)
    receive:

    ASG=FFFF;BVG=0F;CV0=12;

    Telnet
    DAEnetIP3 can be easily accessed via Telnet. Simple password protection mechanizm is provided.
    Note that Telnet is not secure protocol, so it is recommend using only in secure networks.
    On the figure right to the text is shown how DAEnetIP3 controller with IP address 192.168.1.50 is accessed via Telnet with Windows XP.
    Open command line and type:
    telnet "IP of the controller"
    Use the passowrd, in our case this is admin. After correct login the controller responds with welcome message.
    The first command is
    ASG=0000;
    - it sets all 16 DO in low level.
    CV0=?;
    gets the ADC channel 0 value. Its 415; It may be from 0 up to 1023.
    BVG=?;
    gets the eight digital inputs levels. Its 00, which means all inputs are in low level
    ASG=FFFF;
    Sets all the 16 DO in high level.
    Ofcourse these commands are only small part. The full list may be found in the documentation.
    Serial Port
    Each DAEnetIP3 controller may be accessed via UART serial communication. The protocol is given in the documentation. This is provided in case you need RS485 network for example accessed only with one IP address. Each controller has serial address, that is given in each packet sent to the server bridge from user software.
    The figure right to the text shows how 3 DAEnetIP3 controllers are connected in serial network using UART <-> RS485 convertors (not included in the auction). The serial network may be accessed over LAN or WAN with user TCP/IP socket based software.
    Useful Links
    General links
    DAEnetIP3 user's manual -
    here
    How to control DAEnetIP3 with Virtual Serial Port -
    here
    How to connect sensors to DAEnetIP3 (schematics) -
    here
    Software by Denkovi
    DAE-iModules
    - Mobile app for iOS mobile devices, support link
    here
    DAE-aModules
    - Mobile app for Android mobile devices, support link
    here
    DRM Software download and support page -
    here
    DAEnetIP3 Manager software download and support page -
    here
    DAEnetIP3 Command line tool -
    here
    Software examples
    LabVIEW 2011
    - Example how to set/get the DAEnetIP3 I/O status via HTTP GET requests. The code is not public, but a download link will be sent to your email after purchase.
    VB.NET Express 2010
    (
    screenshot
    ) - Example how to access DAEnetIP3 via Virtual Com Port (VCP). There is tutorial how to do this -
    here
    . The executable file is
    here
    .
    VB.NET Express 2010
    - Examples how to access DAEnetIP3 via sockets.
    C#.NET Express 2010
    - Example how to access DAEnetIP3 via HTTP GET commands.
    C++.NET Express 2010
    - Example how to access DAEnetIP3 via HTTP GET commands.
    Visual Basic 6:
    Example1 (TCP socket)
    - acess the I/O lines (does not include RC4)
    download
    .
    Example2 (HTTP GET Requests)
    - communicate with the module using HTTP get requests.
    Borlnad C++ Builder 6
    (
    screenshot
    ) - Example how to acess the I/O lines (does not include RC4) -
    download
    .
    Java (using TCP/IP sockets) - Example how to acess the I/O lines (does not include RC4) -
    download
    .
    Java (using HTTP/API) - Example how to acess the I/O lines (does not include RC4) -
    download
    .
    Visual Basic 6 (HTTP GET Requests)
    - example how to communicate with the module using HTTP get requests.
    Node.js (HTTP GET Requests)
    - example how to communicate with the module using HTTP get requests in Node.js.
    More exaples -
    here
    ;
    Third parity software
    MajorDomo
    - Innovative home automation system. It has web interface, voice control, notifications, GPS tracking and many more features. More information -
    here
    Majordomotic
    - Cloud home automation software by the company EdelBit. It supports all our
    ethernet relays
    and
    ip controllers
    . Additional
    android software
    is available as well. Here we have tried to explain how to work with it together with our hardware -
    https://denkovi.com/majordomotic-with-denkovi-ethernet-relays
    MyDomoticaHd
    - Android software by
    www.phsoftware.altervista.org
    . Additional explanation how to use the software with our
    ethernet relays
    and
    ip controllers
    - here:
    https://denkovi.com/mydomoticahd-with-denkovi-ethernet-relays
    Android application for mobile devices by iSwitch LLC, Android market link -
    here
    , developer's page -
    here
    . Please note if your DAEnetIP3 controller is with firmware version 1.0.0, then RC4 option must be turned off.
    Please note that TFTP firmware upgrade is not anymore supported. From our experience we don't recommend to use it because it is unsafe and can damage your DAEnetIP3 controller. If you would like to upgrade your DAEnetIP3 device with the last firmware version, please contact with us and we will send you instructions.
    Images
    Please read before buy!